Distribution &
Wiring
Solar Power Distribution and Wiring Systems
  • Digital
    7-Day
    Timer  
  • Meters
      
       
  • Delta
    Lightning
    Arrestors  
  • DC
    Current
    Shunts  
  • Go Power!
    Fuses    
     
  • Go Power!
    Fuse
    Blocks  
  • Outback
    AC
    Breakers  
  • Outback
    DC
    Breakers  
  • PS2/PS4
    Breakers
     
SS7 Digital 7-Day Timer

Converts wall switch to a digital timer. Simply push the clear cover to switch on or off at any time. Program up to 6 on/off pairs (12 automatic switch settings). Setting times can be once a week, every day, every weekday, or only on weekends.

Random feature automatically varies switching times for a "lived-in" look for your residence. Rated for 15 amps at 120 VAC and 4 amps at 12 VDC. One year warranty

TM-500 Battery Capacitor Meter

The TM-500 meter can be installed with all inverter and battery systems. Simple installation with plug-in cable connections. Includes a 500 amp shunt and 15 m cable. For 12 - 32 volt systems. For 48 volt systems, the optional TM-48 shunt circuit board is required in addition to the TM-500. The TM-500 can also be used to turn the power on and off for any DR series inverter; you will require an extra cable to use this feature.

TM-48 Shunt Circuit Board

Shunt circuit board for 48 VDC systems.
TM-CBL Remote Control Cable

Second cable for remote control.
TM-2020 TriMetric Battery System Monitor

The Trimetric 2020 battery system monitor is designed for 12-48 volt systems. It displays battery voltage, amps, amp-hours, minimum and maximum battery volts, days since fully charged and days since equalized.
TM-48V TriMetric 48-Volt Adapter/Lighting Protector

Allows for operation of the Trimetric 2020 meter with 48 volt systems and provides lightning protection for 12-48V systems.
TM-500A-50 TriMetric 500A/50mV Shunt

This shunt is for systems with a maximum current of 400 amps continuous with no overloads, or 300 amps continuous with up to a 5 minute overload to 500 amps maximum. Allows “amps” readings as low as 0.1 amps and is suitable for most systems with moderate or large sized inverters.

PM-5000U PentaMetric Battery Monitor System

The PentaMetric battery system monitor consists of three parts. The input unit, display unit and computer interface. The system provides battery monitoring for solar, wind or generator charged systems from 8-100 volts. The monitor can measure up to two battery systems at once. It provides battery monitoring for solar, wind or generator charged systems. It measures volts, amps, amp-hours, temperature, battery cycle efficiency and battery percent full. The system features data-logging to a pc as well as audible and visual alarms.
PM-100C PentaMetric Computer Interface

PM-100D PentaMetric Display Unit
Delta Lightning Arrestors

Lightning arrestors are recommended in any area prone to lightning. They not only protect your regulators and DC loads, but can be installed to protect your inverter as well. Inverters are vulnerable to lightning induced surges, and the repairs are not covered by manufacturers' warranties. A lightning arrestor is insurance against damage. Locate arrestors at the PV array and/or the location where the array cable connects to circuit breaker or charge controller. In addition, lightning arrestors can be located in the main AC circuit panel to protect the system from lightning strikes entering through AC branch circuits.

Models:

A-DC - Lightning arrestor - DC (red/black wires)
LA-AC - Lightning arrestor - AC (white/black)
LA-AC3 - Lightning arrestor - 3 phase

DC Current Shunts

Measure large DC currents with standard volt meters or our GP-DM digital meter (see left). Brass with insulated base. The 100-amp model is scaled to read 1 mV per amp, while the 500-amp model reads 0.1 mV per amp.
 
Go Power! Fuses

Replacement Go Power! Class T Fuses
 

Specifications:
  Description
GP-110-A-DC-fuse 110 Amp DC Fuse
GP-200-A-DC-fuse 200 Amp DC Fuse
GP-300-A-DC-fuse 300 Amp DC Fuse
GP-400-A-DC-fuse 400 Amp DC Fuse

Go Power! Fuse Blocks

Go Power! DC Fuse Blocks are extra heavy duty DC rated fuses, with "slow blow" characteristics suitable for inverter installations. Protect yourself and your equipment! Includes mounting block, fuse and protective cover.

Specifications:

  Description
FBL-110 110 Amp DC Fuse Block
FBL-200 200 Amp DC Fuse Block
FBL-300 300 Amp DC Fuse Block
FBL-400 400 Amp DC Fuse Block
OutBack AC Breakers

These hydraulic-magnetic breakers can be used for input, output or load circuits and are DIN rail "snap-in" mountable. 1/2" (13 mm) wide.

Specifications:

  # poles VAC
OBAC-15 1-pole 120
OBAC-15D 2-pole 120/240
OBAC-20 1-pole 120
OBAC-25D 2-pole 120/240
OBAC-50 1-pole 120
OBAC-50D 2-pole 120/240
AC-30 1-pole 120
AC-30D 2-pole 120/240
AC-60 1-pole 120
AC-60D 2-pole 120/240
OutBack DC Breakers

Panel mounted Hydraulic-Magnetic type breakers which can be used for DC sources, inverters or load circuits. 3/4" (18 mm) wide


Specifications:

  Amps VDC
OBDC250 250 A 125 V
OBDC175 175 A 125 V
OBDC100 100 A 125 V
OBDC60 60 A 125 V
OBDC50 50 A 125 V
OBDC40 40 A 125 V
OBDC30 30 A 125 V
OBDC20 20 A 125 V
OBDC15 15 A 125 V
OBDC10 10 A 125 V
OBDC5 5 A 125 V
OBDC1 1 A 125 V
PS2/PS4 Breakers

Overcurrent protection breakers for the Power System 2 and Power System 4 series of enclosures. AC and DC.

 
Specifications:
  Description
PS4-IOB-60Q AC I/O/Bypass breaker assy.
60A 120/240 VAC
for adding four series stacked
OutBack FX inverter/chargers –
requires 9 brkr. spaces
PS4-IOB-100Q AC I/O/Bypass breaker assy.
60A 120/240 VAC
for adding four series stacked
OutBack FX inverter/chargers –
requires 9 brkr. spaces