- Single
Wavelength
Sensors
- PRO
40
- PRO
50
- TempMatic
4000
Single-Wavelength sensors provide the average temperature of the measured target area. Short wavelength sensors are recommended to reduce or eliminate errors due to emissivity variation. They are offered in a variety of configurations with a wide selection of temperature ranges, optics, and spectral response options. The PRO 42 and 52 models feature a unique auto null design that enables more accurate measurements with short-wavelengths at low temperatures.
|
- Temperature limits 0-4500°F (0-2500°C)
- Accurate, reliable, repeatable measurements
- Wide selection of temperature ranges, optics and spectral response options
- Infrared filtering for glass, plastic and flame insensitivity
- Visual, laser, and fiber optic alignment options
- Auto null balancing for drift free operation
- Fiber optics with low temperature capabilities
(150°F/75°C or greater)
- A variety of installation and protective
accessories
The PRO 42 and 52 models feature a unique auto null design that enables the use of short wavelengths at temperatures as low as 100°F (40°C). This feature enables more accurate and repeatable measurements on applications such as cold rolled steel and low temperature induction heating applications where the metal surface has a low or varying emissivity and the temperatures are below 500°F (260°C). |
|
 |
- Broad Temperature Ranges,
Precise Optics, and Short Operating Wavelengths
- Short Wavelength Spectral Response
- Visual Aiming
(for Fiber Optic choose PRO 50)
- Optional through the lens
laser aiming
- An Intuitive text based user interface
- Programmable outputs and alarms for measured target and ambient temperatures
- Bi-directional RS485 and RS232 communications
- Advanced system diagnostics and status messages
- Rugged, Corrosion Resistant NEMA 4x (IP65) Enclosures
- Stand alone and system configurations
- A wide selection of accessories
The PRO 42 models feature a unique auto null design that enables more accurate measurements on applications such as cold rolled steal and low temperature induction heating processes where the temperatures can go as low as 100°F (40°C) and the surface has a low or varying emissivity.
For most applications, the selection of the sensor is based on the temperature range and the optics that meet the requirements of the application. However, some applications require careful selection of the sensor’s operating wavelength in order to obtain accurate measurements. Frequently, the selection of a specific narrow band filter will result in a narrower temperature range for the sensor, but the benefit can be dramatic improvements in the accuracy and repeatability of temperature measurements. Thoughtful wavelength selection is important in the following applications:
- visually transparent materials, like glass or plastics
- the ability to measure through flames
- the ability to minimize the interference of water vapor or background reflections
| 3.40 to 3.46 µm |
125-1000°F |
50-300°C |
D/14 |
| 3.40 to 3.46 µm |
250-1500°F |
125-425°C |
D/40 |
| 3.40 to 3.46 µm |
300-2500°F |
150-560°C |
D/100 |
| 2.8 to 3.3 µm |
75-400°F |
25-200°C |
D/14 |
| 2.8 to 3.3 µm |
125-800°F |
50-425°C |
D/50 |
| 2.8 to 3..3 µm |
150-800°F |
65-425°C |
D/100 |
| 2.0 to 2.5 µm |
150-800°F |
65-425°C |
D/50 |
| 2.0 to 2.5 µm |
450-2500°F |
230-1375°C |
D/100 |
| 1.5 to 1.65 µm |
500-2100°F |
260-1150°C |
D/100 |
| 1.5 to 1.65 µm |
700-3200°F |
375-1750°C |
D/100 |
| 0.8 to 1.0 µm |
1000-2500°F |
540-1375°C |
D/100 |
| 0.8 to 1.0 µm |
1200-3200°F |
650-1750°C |
D/100 |
| 0.8 to 1.0 µm |
1400-4500°F |
760-2475°C |
D/150 |
(1) These models require a special enclosure for custom optical components.
- 21 - Remote Interface Module with Power Supply
- PS - Universal Power Supply
- AP - Air Purge
- WCAP - Water Cooling Air Purge
- SB - Swivel Bracket
- LA - Laser Aiming
PRO Series Brochure (PDF)
Single Wavelength Temperature Systems Brochure (PDF)
PRO 40 & 50 Datasheet (PDF)
Application Worksheet (PDF)
|
|
 |
- A wide selection of temperature ranges and optics
- Fiber optic alignment with a small, sealed fiber cable
- Optional Integrated Aim Light to verify alignment
- An Intuitive text based user interface
- Programmable outputs and alarms for measured target and ambient temperature
- Bi-directional RS485 and RS232 communications
- Advanced system diagnostics and status messages
- Rugged, corrosion resistant NEMA 4 / IP65 Enclosures
- Stand alone and system configurations
- A wide selection of accessories
All of Williamson’s fiber optic sensors use a small, sealed fiber optic cable with an ambient limit of 400°F (200°C) to enable access to difficult to reach targets and to survive hostile operating conditions. In addition, Williamson offers several unique fiber cable options that can enable measurements on applications that were previously considered difficult to measure. This includes the ArmorGuard System, the Stainless Steel Braid System, and the Gooseneck System.
The PRO 52 models feature a unique auto null design that enables more accurate measurements on applications such as cold rolled steel and low temperature induction heating processes where the temperatures can go as low as 100°F (40°C) and the surface has a low or varying emissivity.
| 2.0-2.5 µm |
200-800°F |
95-425°C |
D/2, D/12, D/50 |
Quartz |
3ft / 91cm |
| 2.0-2.5 µm |
450-2500°F |
230-1375°C |
D/2, D/50, D/75 |
Quartz |
30ft / 9.1m |
| 1.5-1.65 µm |
450-1800°F |
260-980°C |
D/2, D/12, D/50 |
Quartz |
3ft / 91cm |
| 1.5-1.65 µm |
500-2100°F |
315-1150°C |
D/2, D/50, D/75 |
Quartz |
10ft / 3m |
| 1.5-1.65 µm |
700-2750°F |
375-1500°C |
D/2, D/50, D/75 |
Quartz |
30ft / 9.1m |
| 0.8-1.0 µm |
1000-2500°F |
550-1375°C |
D/2, D/12, D/50 |
Glass |
3ft / 91cm |
| 0.8-1.0 µm |
1200-3000°F |
650-1650°C |
D/2, D/50, D/75 |
Glass |
10ft / 3m |
| 0.8-1.0 µm |
1400-4500°F |
750-2475°C |
D/2, D/50, D/75 |
Glass |
30ft / 9.1m |
(1) The High Resolution optics require a larger lens barrel in order to obtain the smaller spot size.
- 21 – Remote Interface Module with Power Supply
- PS – Universal Power Supply
- AL – Integrated Aim Light
- FOSB – Fiber Optic Swivel Bracket
- AP - Air Purge
- WCAP - Water Cooling Air Purge
- AG - ArmorGuard System
- SSB - Stainless Steel Braid System
- GN - Gooseneck System
PRO Series Brochure (PDF)
Single Wavelength Temperature Systems Brochure (PDF)
PRO 40 & 50 Datasheet (PDF)
Application Worksheet (PDF)
|
|
 |
- A wide selection of temperature
ranges and optics
- A variety of Spectral response options that include infrared filtering for glass, plastic,
and flame insensitivity
- Visual Aiming
- Optional Laser Aiming
- Rugged, corrosion resistant
NEMA 4 / IP65 enclosures
- Stand alone and system configurations
- A wide selection of accessories
For most applications, the selection of the sensor is based on the temperature range and the optics that meet the requirements of the application. However, some applications require careful selection of the sensor’s operating wavelength in order to obtain accurate measurements. Frequently, the selection of a specific narrow band filter will result in a narrower temperature range for the sensor, but the benefit can be dramatic improvements in the accuracy and repeatability of temperature measurements. Thoughtful wavelength selection is important in the following applications:
- visually transparent materials, like glass or plastics
- the ability to measure through flames
- the ability to minimize the interference of water vapor or background reflection
|
| 8-14 µm |
0-500°F |
0-250°C |
D/60 |
D/80 |
| 8-14 µm |
0-1000°F |
0-550°C |
D/60 |
D/80 |
| 8-14 µm |
200-1000°F |
100-550°C |
D/60 |
D/80 |
| 8-14 µm |
300-2000°F |
150-1100°C |
D/60 |
D/100 |
|
| 3.7-3.9 µm |
400-1400°F |
200-750°C |
D/60 |
N/A |
| 3.7-3.9 µm |
600-1800°F |
300-975°C |
D/60 |
N/A |
| 3.7-3.9 µm |
800-2200°F |
425-1200°C |
D/100 |
N/A |
| 3.7-3.9 µm |
1200-3000°F |
650-1650°C |
D/100 |
D/150 |
| 3.7-3.9 µm |
2000-4000°F |
1100-2200°C |
D/100 |
D/150 |
|
| 4.9-5.3 µm |
200-1000°F |
100-550°C |
D/60 |
N/A |
| 4.9-5.3 µm |
500-1500°F |
250-800°C |
D/100 |
N/A |
| 4.9-5.3 µm |
500-1500°F |
250-1375°C |
D/100 |
D/150 |
| 4.9-5.3 µm |
1000-4000°F |
550-2200°C |
D/100 |
N/A |
|
| 7.6-8.4 µm |
85-600°F |
30-300°C |
D/60 |
N/A |
| 7.6-8.4 µm |
200-1000°F |
100-550°C |
D/60 |
D/80 |
| 7.6-8.4 µm |
500-1500°F |
250-800°C |
D/100 |
D/150 |
| 7.6-8.4 µm |
500-2500°F |
250-1375°C |
D/100 |
D/150 |
(1) Operating Wavelength for CO2 Gases to measure flames
- 20 – Remote Display with power supply
- 22 – Remote Display with 2 relays and a power supply
- PS110 or PS220 – AC Power Supply
- LA – Laser Aiming
- SB – Swivel Bracket
- AP - Air Purge
- WCAP - Water Cooling Air Purge
PRO Series Brochure (PDF)
Single Wavelength Temperature Systems Brochure (PDF)
Application Worksheet (PDF)
|
|